NEC SV8500 Operation And Maintenance Manual - 4-S:
– 249 –
CHAPTER 3
System Messages
4-S:
MUX Ready Failure
This message displays when the MUX (PH-PC36) card has a Ready Failure in one of the dual systems. When
the card is not ready for service because of the failure or because the card is not mounted properly, the system
creates this message.
Unit and MG number for MUX card
with ready fault
MG and system number for faulty
MUX card
Reference:
See
Unit Fault - ACT-Side MUX Card Is Faulty and System Has Changed Over
procedure.
Default Alarm
Default Grade
Grade Modified
Lamp Modified
MN
3
1:
XXXX
0000
0000
0000
2:
0000
0000
0000
0000
3:
0000
0000
0000
0000
4:
0000
0000
0000
0000
5:
0000
0000
0000
0000
6:
0000
0000
0000
0000
7:
0000
0000
0000
0000
8:
0000
0000
0000
0000
9:
0000
0000
0000
0000
b7
b6
b5
b4
b3
b2
b1
b0
b7
b2
b1
b0
1 2
b0:
0/1 = -/MUX ready fault in even-numbered MG, Unit 0
b1:
0/1 = -/MUX ready fault in even-numbered MG, Unit 1
b2:
0/1 = -/MUX ready fault in even-numbered MG, Unit 2
b3:
0/1 = -/MUX ready fault in even-numbered MG, Unit 3
b4:
0/1 = -/MUX ready fault in odd-numbered MG, Unit 0
b5:
0/1 = -/MUX ready fault in odd-numbered MG, Unit 1
b6:
0/1 = -/MUX ready fault in odd-numbered MG, Unit 2
b7:
0/1 = -/MUX ready fault in odd-numbered MG, Unit 3
1
b0:
MG number for faulty MUX card
0/1 = Even number/Odd number
b1:
0/1 = Ready failure in MUX System 0/Ready failure in MUX System 1
b2:
ACT or STBY status of faulty MUX.
0/1 = ACT/STBY
2