NEC SV8500 Operation And Maintenance Manual - page 324
– 277 –
CHAPTER 3
System Messages
6-O: SMDR Output Buffer Overflow Alarm
This message displays when the SMDR output buffer usage rate has exceeded the value assigned to ASYD,
SYS1, INDEX 249.
Detail Information
(a) FS = 0, FE = 0/1
Default Alarm
Default Grade
Grade Modified
Lamp Modified
SUP
1
1:
XXXX
XXXX
0000
0000
2:
0000
0000
0000
0000
3:
0000
0000
0000
0000
4:
0000
0000
0000
0000
5:
0000
0000
0000
0000
6:
0000
0000
0000
0000
7:
0000
0000
0000
0000
8:
0000
0000
0000
0000
9:
0000
0000
0000
0000
b7
b6
b5
b4
b3
b2
b1
b0
b7
b0
1 2
3 4
b0-b3: FS
b4-b7: FE
This system message varies depending on the data.
FS
FE
MEANING
(a)
0
0
SMDR output buffer usage rate exceeds the value
assigned by ASYD, SYS1, INDEX 249.
(a)
0
1
After SMDR output buffer usage rate exceeds the
value assigned by ASYD, SYS1, INDEX 249,
usage rate lowered less than the value assigned by
INDEX 250.
(b)
1
0
-
(c)
2
0
Data output is impossible due to SMDR apparatus
failure.
1
b0:
0/1 = Data assigned by the ASYD, SYS1, INDEX 249, 250 is valid/
invalid
2