1
70 to 7E
:
This is the 15 group numbers.
7F
:
This is a broadcast ID that all devices listen to.
In grandMA2 the device ID and group ID can be set for both incoming and outgoing messages.
For transmitting MSC it can only transmit one octet in the
Device ID
location. The
Send to
setting (described
above) selects which one of the three different sections Id that should be transmitted.
Command Format
The command format octet denotes the type of equipment that should receive the message (or at least respond).
grandMA2 only transmit and respond to three different formats:
01
:
This is the
General Lighting
format
02
:
This is
Moving Lights
format.
7F
:
This is an
All
format that all equipment should respond to.
Command
The command octet denotes the type of command in the message. The command type will dictate the data
information.
grandMA2 supports 7 different command types:
01 (Go)
:
This is the same as a Goto command in grandMA2. It needs to be followed by a cue number.
02 (Stop)
:
This is the same as a Pause command in grandMA2. This can be followed by a cue number.
03 (Resume)
:
This will "un-plause" a cue. If a specific cue has been paused, then the cue number needs to be specified with
this command.
04 (Timed_Go)
:
This can be used to perform a Goto with a specific fade time. It needs both the time and the cue number - in
that order.
06 (Set)
:
Set can be used to set the position of faders. It needs the fader number and page followed by the position.
07 (Fire)
:
This can be used to trigger macros. The macro number needs to follow the command. Only macro 1 to 255 can
be triggered.
0B (Go_Off)
:
This command can be used "Off" executors. This needs to followed by a cue number.
1091