MA Lighting grandMA2 User Manual - page 372
© 2017 MA Lighting Technology GmbH | Dachdeckerstr. 16 | D-97297 Waldbüttelbrunn | Germany
Phone +49 5251 688865-30 | tech.support (at) malighting.com | www.malighting.com
Version 3.3
1
9.2.122. Goto Keyword
To get the Goto keyword in the command line press
Goto
.
Another way is to type
Goto
or the shortcut
Got
in the command line.
Description
Goto is a function keyword to jump in a list. Set the fade time for Goto in the
Setup I Show I Playback & MIB
Timing I Goto
.
Syntax
Goto [Cue object] [Executor object] / [Option] = [Option Value]
Options
To get a list of all available options to the Goto keyword type in the command line:
[Channel]> Goto /?
The Goto keyword has the following options:
Option
Option
Shortcut
Option Value
Option
Value
Shortcut
Description
cue_mode cm
Normal
N
Normal Goto mode.
cue_mode cm
Assert
A
Goto with assert in the
original timing.
cue_mode cm
XAssert
XA
Goto with assert in the
cuetiming of current cue.
cue_mode cm
Release
R
Goto finishes the fade-in and
switches the executor off.
userprofile upr
"Name of the user
profile", e.g. "Klaus"
not
available
Normal Goto mode with
specified user profile.
Examples
To go to cue 3 of the selected executor type in the command line:
[Channel]> Goto Cue 3
To go to cue 5 of executor 4 type in the command line:
[Channel]> Goto Cue 5 Executor 4
372