9.2.32. Block keyword
Block
is a function used to add data to prevent tracking. Tracking values (magenta colored) are converted to stored
values (white colored).
To execute this keyword type
Block
or the shortcut
Blo
into the command line.
Syntax
Block [Object-list] If [Selection-list] If [Attribute-list]
Options
To get a list of all available options for the keyword Block in the command line feedback window type the following
into the command line:
[Channel]> Block /?
The keyword Block has the following options:
Option
Shortcut
Option value
Description
defaultvalues
dv
no option value
Removes default values.
trackingshield
ts
no option value
Uses tracking shield.
If the object list does not contain any references to any cues, the Block function is applied to the current cue of the
selected executor.
If syntax does not contain any selection list filter, all fixtures will be used.
If syntax does not contain any attribute list filter, all attributes will be used.
Examples
[Channel]>
Block
Blocks all parameters in current cue of the selected executor.
[Channel]>
Block Cue 5 If Fixture 4 If Feature "Position"
Blocks pan and tilt of Fixture 4 in cue 5 of the selected executor.