7.1.7. Time Control
The time control is located right beside the encoder bar on screen 2.
It is two on-screen faders controlling two different timing elements. They are called
Program Time
and
Exec Time
(Executor Time).
It could look like this:
Time Control
The two faders can be used to set a time. The default maximum is 10 seconds. This maximum value can be
changed in Setup->User->
The bottom of screen 2 can be changed on the grandMA2 onPC. This will make it fit the hardware on a grandMA2
onPC Command Wing. This will hide the Time Control. Please read the
for details
about turning this On or Off.
The fader can still be assigned to physical faders.
The virtual control can be created on any screen using the
CMD Section window
. This can be found in the
Other
tab
in the
.
Program Time
The Program Time can be used to add a fade time to changes in programmer values. Set the fader to the desired
value and activate the Program Time by pressing the On executor key or tap the
Set Time
button so there is a red
marker. Now the set time will be used for all value changes in the Programmer.
To deactivate it tap the
Set Time
button again or press the Off executor key. The red marker should disappear.
It is also possible to use the fader as a manual cross fade from old to new values. Tap the
Manual Xfade
button or
press the MFX executor key to activate the crossfade function - a green marker appears. The master will move to the
lowest position (if it is not already there). Change the value to the new values - the output will not change! Move the
fader from the lowest to the highest position to fade into the new values. The green marker will flash while the cross