MA Lighting grandMA2 User Manual - page 455
© 2017 MA Lighting Technology GmbH | Dachdeckerstr. 16 | D-97297 Waldbüttelbrunn | Germany
Phone +49 5251 688865-30 | tech.support (at) malighting.com | www.malighting.com
Version 3.3
1
Description
With the Preset keyword you can:
Select the fixtures stored in a preset.
At a preset to the fixture or channel selection.
If no fixtures or channels are selected in the programmer, the default function is
SelFix
. For more information, see
.
If fixtures or channels are selected in the programmer, the default function is
Syntax
Preset [ID]
Preset [Preset-type].[ID]
Preset "Name"
Assign Preset [ID] / [Parameter] = [Parameter Value]
Parameter
The following table displays the assignable parameters via command line.
Parameter Parameter Value
Description
Name
"PresetName"
Assign the preset pool name.
Special
"Normal", "Default",
"Highlight", "Stage"
Assign the special mode. For more information,
see
Info
"additional
information"
Assign additional information. Assigned
information are displayed in the
Examples
Select the fixtures stored in preset 5 of the selected preset type, e.g. dimmer.
[Channel]> Preset 5
Sets current selection to the second preset of preset type 3 (gobo).
[Channel]> At Preset 3.2
Select all fixtures stored in any preset with the label "DarkRed".
[Channel]> Preset *."DarkRed"
9.2.214. PresetType Keyword
455