The LoadShow has the following options:
Option
Option
shortcut
Description
full
f
Clears the following data if from a new show will be loaded.
Loads the following data if from an existing show will be
loaded.
- Show data
- Global Settings
- Network Protocols
- User Profiles
- Time Config
- Local Settings
- Network Config
globalsettings g
Clears the global settings if from a new show will be loaded.
Loads the global settings if from an existing show will be
loaded.
localsettings
l
Clears the local settings if from a new show will be loaded.
Loads the local settings if from an existing show will be
loaded.
network
n
Clears the network configuration if from a new show will be
loaded. Loads the network configuration if from an existing
show will be loaded.
noconfirm
nc
Suppress the warning pop-up that asks if you want to save the
show file first.
nodata
No
shortcut
available
Keeps the current show data in the new show (column one in
the setup).
nosave
ns
Does not save the current show file.
protocols
p
Clears the network protocols if from a new show will be
loaded. Loads the network protocols if from an existing show
will be loaded.
save
s
Saves the current show file.
timeconfig
t
Clears the time config.
user
u
Clears the user profiles.
Examples
To load the show file with the file name "Macbeth", type in the command line:
[Channel]> LoadShow "Macbeth"
406