MA Lighting grandMA2 User Manual - page 575
© 2017 MA Lighting Technology GmbH | Dachdeckerstr. 16 | D-97297 Waldbüttelbrunn | Germany
Phone +49 5251 688865-30 | tech.support (at) malighting.com | www.malighting.com
Version 3.3
1
[Object-type1] "Name"
[Object-type1] "Nam*"
Important:
In a selection list, contrary to the object list, each object type is broken down to its corresponding fixture
objects. These fixture objects form the selection list.
If an object type is missing, the object type that was entered last will be used.
If no object type is given altogether, the current object type default of the command line will be used.
If there is no ID before or after
Thru
,
the first or last available ID will be used.
If there is no ID for an object type, the current, active or next ID will be used, depending on the function applied.
If the reference of an object type is nonexclusive, significant parent objects will be broken down by user defaults
and currently selected or active objects.
Example:
[Channel]>
Fixture
3
+ Channel
6
Selects fixture 3 and channel 6.
[Channel]>
Cue Thru
3
- Channel
4
Selects fixtures in first 3 cues, but does not select channel 4.
[Channel]>
Group
3
+ Cue
4
Selects fixtures in group 3 and fixtures in cue 4.
9.3.3. Executor List
575