MA Lighting grandMA2 User Manual - page 529
© 2017 MA Lighting Technology GmbH | Dachdeckerstr. 16 | D-97297 Waldbüttelbrunn | Germany
Phone +49 5251 688865-30 | tech.support (at) malighting.com | www.malighting.com
Version 3.3
1
You can also type
Store
in the command line or use the shortcut
S
.
Description
The store keyword, stores functions in the show file.
If no object-type or destination is given, the object-type
Cue
will be used for the sequence of the selected executor.
Store is a function keyword.
Syntax
Store [object-list] "Name" / [option] = [option value]
Options
To get a list of all available options to the store keyword, type in the command line
[Channel]> Store /?
The store keyword has the following options.
Option
Option
Shortcut
Option Value
Description
addnewcontent an
False, True
False is the same as originalcontent.
auto
not
available
no option value
Stores preset values with the default
preset scope.
cueonly
co
False, True
Prevents changes to track forward.
effects
ef
False, True
Filters or enables effect layer.
embedded
e
False, True
Creates embedded preset.
global
g
no option value
Stores preset with global values.
keepactive
ka
False, True
Keeps values active.
noconfirm
nc
no option value
Suppress stores confirmation pop-up.
originalcontent or
False, True
Stores the original content of the
preset, effect, or cue. False is the
same as addnewcontent.
presetfilter
p
False, True
Sets preset filter on or off.
screen
not
available
1..6
Stores view with selected screen.
selective
s
no option value
Stores preset with selective values.
source
so
Prog, Output, Dmx
In
Defines data source.
tracking
t
False, True
Stores with tracking. False is the same
as cueonly.
trackingshield
ts
no option value
Use tracking shield for store.
universal
u
no option value
Stores preset with universal values.
529