MA Lighting grandMA2 User Manual - page 624
© 2017 MA Lighting Technology GmbH | Dachdeckerstr. 16 | D-97297 Waldbüttelbrunn | Germany
Phone +49 5251 688865-30 | tech.support (at) malighting.com | www.malighting.com
Version 3.3
1
The MA switch has a lot of settings and controlling or configuring it from the console/onPC is all described in the
section.
Bridge
The Bridge is not implemented, so there is nothing to do in this tab.
12.5.4. How to end or leave a session
A single station can be removed from a session or the entire session can be ended.
Leave a session
Leaving the session can be done using the
. This will remove the station, where the
command is executed, from the session.
You can also open the
MA Network Control
(in Setup) and tap the
Leave Session
button.
This only takes one console out of the session - the one you are operating. If there are other stations in the session,
then the session will continue. If your station was the last one, then the session will end.
Disconnect / Dismiss a station
A station can be removed from the session by using the
You can also open the
MA Network Control
(in Setup) select the station you want to remove and tap the
Dismiss Session
button.
This will take the selected station out of the session.
End Session
You can end the session your are a part of using the
You can also open the
MA Network Control
(in Setup) and tap the
End Session
button.
Ending a session will dismiss all stations and the session is no longer running.
12.5.5. Session Collision
You might experience a Session Collision at some point.
It is a situation that occurs when two stations believe that they are the master of the same session.
This can happen if you have a faulty network cable, a bad switch or someone who manually unplugs and re-plugs
network cables.
When this happens, then the session is divided into two parts.
One of the stations that have left the original session, will become master - if it was not already.
624