MA Lighting grandMA2 User Manual - page 269
© 2017 MA Lighting Technology GmbH | Dachdeckerstr. 16 | D-97297 Waldbüttelbrunn | Germany
Phone +49 5251 688865-30 | tech.support (at) malighting.com | www.malighting.com
Version 3.3
1
Important:
When At applies a range/list the values/objects are usually spread across the receiving objects, e.g.,
Fixture 1 Thru 3 At 0 Thru 100 will set 1 At 0, 2 At 50, and 3 At 100. However, there is one exception to
this rule: If the applied range is a list of cues from a tracking sequence, all fixtures will be set to all cues.
Thus, you can apply the tracking status of a cue with the At function (At Cue Thru x).
Example:
[Channel]>
At 75
Sets the dimmer attributes of current selection to 75%.
[Channel]>
At Cue 3
Sets the current selection to the values of Cue 3 from the selected executor.
[Channel]> Fixture 2 At Fixture 3
Selects Fixture 2 and sets it to the values of Fixture 3.
[Channel]> Executor 3 At 50
Sets the fader of Executor 3 to 50%.
[Channel]> Attribute "Pan" At 20
Sets the pan attributes of current selection to 20.
269