MA Lighting grandMA2 User Manual - page 348
© 2017 MA Lighting Technology GmbH | Dachdeckerstr. 16 | D-97297 Waldbüttelbrunn | Germany
Phone +49 5251 688865-30 | tech.support (at) malighting.com | www.malighting.com
Version 3.3
1
MasterGo
"on", "off",
"go", "top"
Assigns the action that is executed if the master fader is
above zero. For more information see
MIBAlways
"on", "off"
Assigns if MIB always is on or off. For more information
see
Advanced executor functionality - Executor options.
MIBNever
"on", "off"
Assigns if MIB never is on or off. For more information see
Advanced executor functionality - Executor options.
OffTime
e.g. "3" (=
3
seconds)
Assigns executor off time in seconds.
OoO
"on", "off"
Assigns if off on overwritten is on or off.
PlaybackMaster
"1 - 50"
0 = No
Playback
Master
Assigns the executor to the specified playback master.
Advanced executor functionality
- special masters - playback masters
Prepos
"on", "off"
Assigns if Auto Prepos is on or off. For more information
see
Advanced executor functionality - executor options
Priority
"super" or
0
"swap" or
2
"htp" or 3
"high" or
4
"ltp" or 5
"low" or 6
Assigns the executor priority. For more information see
Cues and sequences - Playing back cues
RateMaster
0 - 16,
0 = Rate
Individual
Assigns the rate master. For more information see
Advanced executor functionality - Executor options
.
Restart
"First"
"Current"
"Next"
Assigns the restart mode. For more information see
SoftLTP
"on", "off"
Assigns if soft LTP is on or off. For more information see
Cues and sequences - Playing back cues
Parameter
Parameter
Value
Description
348