MA Lighting grandMA2 User Manual - page 462
© 2017 MA Lighting Technology GmbH | Dachdeckerstr. 16 | D-97297 Waldbüttelbrunn | Germany
Phone +49 5251 688865-30 | tech.support (at) malighting.com | www.malighting.com
Version 3.3
1
9.2.220. Profile Keyword
To get the Profile keyword in the command line, type
Profile
or the shortcut
Pro
in the command line.
Description
The Profile keyword is an object keyword to access DMX profiles and DMX profiles points. For more information, see
.
Syntax
[Function] Profile [DMX Profile ID].[DMX Profile Point ID]
Assign Profile [DMX Profile ID].[DMX Profile Point ID] /[Parameter]=[Parameter Value]
Parameter
The following table displays the assignable parameter for
DMX profiles
via command line.
Parameter
Parameter Value
Description
Name
"80%"
Name of the DMX profile.
The following table displays the assignable parameter for
DMX profile points
via command line.
Parameter
Parameter Value
Description
X
0...1
Assign the x position
in physical values of the
point.
Y
0...1
Assign the y position in
physical values of the point.
Example
To export DMX profile 1 from the grandMA2 onPC to the folder C:\ProgramData\MA Lighting
Technologies\grandma\gma2_V_3.1\importexport:
1. Type in the command line:
[Channel]> Export Profile 1
2. Press
Please
.
The DMX profile 1 is exported as a .xml file.
9.2.221. Protocol Keyword
To go to the Protocol keyword, type
Protocol
in the command line or use the shortcut
Prot
.
462