9.2.5. + [Plus] keyword
+ [Plus] is a helping keyword with various functions.
To execute the keyword
+ [Plus]
, type
+
in the command line.
Syntax:
+ [Plus] is used to combine multiple objects in a list or to indicate a relative value. When used as a relative
indicator, with no value given, the value of 1 will be used.
If used as a starting keyword, + creates a selection list, which will be added to the current selection.
Examples:
[Channel]> Delete Cue 1 + 2
Deletes cue 1 and 2 from the selected executor.
[Channel]> At + 5
Adds 5 % to the current dimmer value.
[Channel]> + 5 Thru 7
Adds channel 5, 6 and 7 to the current selection.
[Channel]> Page +
Same as Page + 1, which calls the next page.
Hint:
To execute this function, you can also use the key
+
on the console.
For more information see
.
9.2.6. AddUserVar keyword
AddUserVar
is a function used to change/extend content of user specific variables.
To execute the keyword AddUserVar type
AddUserVar
or the shortcut
AddU
into the command line.