1
StatusCall
"On", "Off"
Assign, if the timecode show will:
Sync with the timecode signal instantly (on)
Execute the signal when they are reached (off)
TimeUnit
"1/100 Seconds", "24
FPS", "25 FPS", "30
FPS"
Assign the time unit for the graphic display mode.
WhenEnding
"Stop", "Pause"
Only for timecode shows syncing to the internal clock.
Assign what happens when the timecode show runs out of
recorded time.
WhenStopping
"Do Nothing", "Rewind"
Assign what happens when the timecode show is stopped.
AutoStart (only
available with
external timecode
slot)
"Off", "On"
Only available when syncing to an external source.
If a timecode signal is received, the timecode show switches
from the off mode into the play mode.
User Bits
0 .. FFFFFFFF, 0 ..
4294967296
Only available when syncing to an external source.
Assign user bits in hex or decimal, to transmit several kinds of
information, e.g. a second Timecode Stream. So several
incoming Timecode Streams can be discerned.
Info
"Information Text"
Assign additional information.
Parameter
Parameter Value
Description
Examples
Store new timecode show 2 in the timecode pool.
[Channel]> Store Timecode 2
Record executor action for timecode show 2.
[Channel]> Record Timecode 2
Pool Object Record Timecode
Play timecode show 2.
[Channel]> Go Timecode 2
Pool Object Go Timecode