Program 10 : System Configuration Setup
Description
Use Program 10-41 : General Purpose Contact Detector to assign System
Number/Slot Number, ESIU Port Number and Circuit Number settings used by the
PGD(2)-U10 ADP.
Conditions
None
Feature Cross Reference
None
Program 10 : System Configuration Setup
10-41 : General Purpose Contact Detector
Level:
IN
Input Data
System Number
1~50
Input Data
Slot Number
1~24
Input Data
Item
No.
Item
Input Data
Default
01
System Number/Slot
Number
The User can set the
System ID when NetLink
is active.
ESIU Slot No. used by
PGD(2)-U10 ADP.
System No. Slot No.
0 = Not Used 0 = No Setting
1 ~ 50 1 ~ 24
0
02
ESIU Port Number
ESIU Port No. used by
PGD(2)-U10 ADP.
0 = No Setting
1 ~ 16
0
03
Circuit Number
Circuit No. of PGD(2)-U10
ADP Line Number.
0 = No Setting
1 ~ 2 = Line No.
0