NEC Univerge SV8100 Programming Manual - 32-03 : Door Box Basic Setup
UNIVERGE SV8100
Issue 11.0
SV8100 Programming Manual
2 - 439
Description
Use Program 32-03 : Door Box Basic Setup to select the chime pattern and gain
level for each Door Box. There are six distinctive chime patterns. The chime tones are
defined in
80-01 : Service Tone Setup on page 2-657
The Door Box feature is called Door Phone when programming via WebPro and
using a multiline terminal.
Conditions
None
Feature Cross Reference
Door Box
Program 32 : Door Box and Sensor Setup
32-03 : Door Box Basic Setup
Level:
IN
Input Data
Door Box Number
1~8
Item
No.
Item
Input Data
Default
01
Chime Pattern
0 = None
1 = Door Box Ring 1
2 = Door Box Ring 2
3 = Door Box Ring 3
4 = Door Box Ring 4
5 = Door Box Ring 5
6 = Door Box Ring 6
Door Box 1 = 1
Door Box 2 = 2
Door Box 3 = 3
Door Box 4 = 4
Door Box 5 = 5
Door Box 6 = 6
Door Box 7 = 1
Door Box 8 = 1
02
CODEC Transmit Gain Setup
(PGD(2)-U10 ADP to Door
Box)
1~63 (-15.5dB ~ +15.5dB)
32
03
CODEC Receive Gain Setup
(Door Box to PGD(2)-U10
ADP)
1~63 (-15.5dB ~ +15.5dB)
32