NEC Univerge SV8100 Programming Manual - page 886
Issue 11.0
UNIVERGE SV8100
2 - 844
Program 90 : Maintenance Program
40
0
0
CS error noti-
fication 2.
CS detected the factor that
the noise is generated
between CS-PS, BBIC
reset was executed, and it
was restored automatically.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU
unit with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Confirm CS is
normally connected.
2. Confirm the wiring
between CSIU-CS is
normal.
3. Exchange CS.
4. Exchange CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
41~49
--- Reserved ---
50
1
0
System Start
Notification
The system started.
The system was
started.
No action needed.
51
0
0
System Data
change
CD-CP00-US Upgrade is
performed or Programming
change is made.
No action needed.
52
0
0
VRS/InMail
CF available
space
Provide alarm when the
available space on the
VRS/InMail CF card is
getting below threshold.
0 = Not Set, no
alarm provided
1 = Major, when the
avail. space gets
below 3%
2 = Minor, when
the avail. space
gets below 10%
Have users remove
stored messages, or if
needed, use InMail
Utility to reinitialize CF
back to factory default.
This error can
be recovered
when avail.
space on
VRS/InMail
CF is back
above 3% or
10%,
depending on
alarm level
setting.
53
0
0
--- Reserved ---
54
2
0
License
Management
Table Full
A new TCP/IP terminal and
the DSP board were not
able to be added to the
application license
management table.
• The license management
table is registering full.
Maximum 512
license information
on the TCP/IP
terminal is
registered, and a
new terminal
cannot be
registered.
Delete license
information on an
unnecessary TCP/IP
terminal with PRG
90-44.
WAR
55
2
0
Regular
maintenance
exchange
notification.
The regular maintenance
exchange day has passed.
• The regular
maintenance
exchange day
that had been set
with PRG 90-51
exceeded it.
Do the maintenance
exchanges of pertinent
parts, and set the next
regular maintenance
exchange day with
PRG 90-51.
The excess
on the regular
maintenance
exchange day
is canceled by
changing
PRG 90-51 or
when the
function is
invalidated,
the error is
recovered.
ERR
REC
56
--- Reserved ---
Table 2-20 Description of Alarm (Continued)
Alarm
No.
Type
Report
Name
Content of Alarm
Cause
Action
Recovery
Alarm