NEC Univerge SV8100 Programming Manual - page 885
UNIVERGE SV8100
Issue 11.0
SV8100 Programming Manual
2 - 843
32
1
0
Remote
watch
function
performs auto
dial.
Remote watch function
performs auto dial.
No action needed/
33
1
0
Fail to auto
dial by
security
function.
Fail to auto dial by security
function.
All auto dial trunks
are busy.
No action needed.
34
--- Reserved ---
35
0
0
CS Blocking
The link of the CSIU and
CS came off.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU
unit with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1 Confirm CS is
normally connected.
2. Confirm the wiring
between CSIU-CS is
normal.
3. Exchange CS.
4. Exchange CSIU.
The error is
recovered
when
reconnecting
or exchanging
it.
ERR
REC
36
0
0
CS error
notification 1
CS detected the problem
occurring in the air
synchronous signal
between CS-CSIU, BBIC
reset was executed, and it
was restored automatically.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU
unit with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Confirm CS is
normally connected.
2. Confirm the wiring
between CSIU-CS is
normal.
3. Exchange CS.
4. Exchange CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
37
0
0
CS
transmission
error.
Because CS had not
returned the response to
the control signal from a
main device longer than
the fixed time, it was
restored automatically
specifying reset to
concerned CS with a main
device.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU
unit with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Confirm CS is
normally connected.
2. Confirm the wiring
between CSIU-CS is
normal.
3. Exchange CS.
4. Exchange CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
38
0
0
CSIU Dch
Error×
It was restored
automatically specifying
reset to concerned CS with
a main device because a
main device had detected
the control signal from a
main device not normally
reaching CS.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU
unit with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Confirm CS is
normally connected.
2. Confirm the wiring
between CSIU-CS is
normal.
3. Exchange CS.
4. Exchange CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
39
0
0
CSIU trans-
mission error.
This alarm is integrated
into Communication fault
between the CD-CP00-US
and other PKG, and it is
not used in SV8100.
Table 2-20 Description of Alarm (Continued)
Alarm
No.
Type
Report
Name
Content of Alarm
Cause
Action
Recovery
Alarm
Status