NEC Univerge SV8100 Programming Manual - page 857
UNIVERGE SV8100
Issue 11.0
SV8100 Programming Manual
2 - 815
28
RTP TX Level Control
Select transmit level control mode.
0 = Disable
1 = TX Level Control Mode
2 = TX Automatic Level Control
Mode
3 = TX HLC (high Level)
0
29
RTP TX Voice Level Control
Mode
Effective when 84-31-28 = 1
0~16 (-24 ~ +24)
0 = -24dB
1 = -21dB
:
8 = 0dB
:
15 = 21dB
16 = 24dB
8
30
RTP RX Automatic Level Control
Level
Normally not used. Select target
gain. Effective when 84-31-28 = 2
0~12 (-42 ~ -6)
0 = -42dBm
1 = -39dBm
:
7 = -21dBm
:
11 = -9dBm
12 = -6dBm
7
31
RTP TX HLC Threshold
Select HLC threshold level.
Effective when 84-31-28 = 3
0~42 (-42 ~ 0)
0 = -42dBm
1 = -41dBm
:
41 = -1dBm
42 = 0dBm
42
32
RTP TX Gain Compression
Mode
Transmit Gain Compression on or
off. Effective when 84-31-28 = 3
0 = Disable
1 = Enable
1
33
RTP TX Gain Compression
Threshold
Transmit Gain Compression on or
off. Effective when 84-31-32 = 1
0~42 (-42 ~ 0)
0 = -42dBm
1 = -41dBm
:
41 = -1dBm
42 = 0dBm
42
34
RTP RX Level Control
Normally not used. Select receive
level control mode.
0 = Disable
1 = RX Level Control Mode
2 = RX Automatic Level Control
Flag
0
Input Data (Continued)
Item
No.
Item
Input Data
Default