NEC Univerge SV8100 Programming Manual - page 317
UNIVERGE SV8100
Issue 11.0
SV8100 Programming Manual
2 - 275
Description
Use Program 20-19 : System Options for Caller ID to define the system options for
the Caller ID feature.
Program 20 : System Option Setup
20-19 : System Options for Caller ID
Level:
IN
Input Data
Item
No.
Item
Input Data
Default
01
Caller ID Displaying Format
(if displaying digits are more than 12 digits)
0 = First 10 digits
(Upper)
1 = Last 10 digits
(Lower)
0
02
--- Not Used ---
03
Caller ID Edit Mode
0 = Off
1 = On
0
04
Wait Facility IE Timer
This timer is used with ISDN trunks to determine the time
the system waits for the Caller ID name from the Telco.
0~64800 seconds
10
05
Caller ID Sender Queing Time (Sender Wait)
0~64800 seconds
0
07
Long Distance Code
Up to two digits
1
08
Area Code
Up to six digits
No
setting
09
Calling Party Name for ISDN Trunk
When set, sends the Calling Party Name to the network.
Up to 12
characters
No
setting
10
Message Type Treated as CID for Analog Trunk
Specify message type number which treats as Caller ID
from analog trunk.
0 = ‘2’ only
1 = ‘2’ and ‘3’
1