2 - 690
Program 81 : Basic Hardware Setup for Trunk
Conditions
None
Feature Cross Reference
ISDN Compatibility
12
T313
Specify the timer value started when
connection request is sent. Valid
range 1 ~ 4 seconds in 1 second
increments. Value of 0 indicates timer
not used.
1~254 (sec)
4
13
T314
Specify the timer value started when
message segment is received.
1~254 (sec)
4
14
T316
Specify the timer value started when
RESTART is sent.
(T317+1)~254 (sec)
120
15
T317
Specify the timer value started when
RESTART is received.
1~(T316-1)
60
16
T318
Specify the timer value started when
RES is sent. This timer is valid for
user side use only.
1~254 (sec)
4
17
T319
Specify the timer value started when
SUSPEND is sent. This timer is valid
for user side use only.
1~254 (sec)
4
18
T320
Specify the timer value when
B-channel access: connection is
received, or D-channel access:
DL-ESTABLISH confirmation or
indication is received.
1~254 (sec)
30
19
T321
Specify the timer value started when
STATUS ENQ is received.
1~254 (sec)
30
20
T322
Specify the timer value upon
D-channel failure.
1~254 (sec)
4
Item
No.
Item
Description
Input Data