NEC Univerge SV8100 Programming Manual - page 824
Issue 11.0
UNIVERGE SV8100
2 - 782
Program 84 : Hardware Setup for VoIP
49
RTP Filter
To avoid incorrect voice pass
connection, this Program
checks the sending side
address from received RTP
packet at VoIPDB.
0 = Disable
1 = Enable
1
50
FAX Relay Mode
0 = Disable
1 = Enable
0
51
T.38 Protocol Mode
0 = R/U
1 = U/R
2 = RTP
3 = UDPTL
1
52
FAX Maximum Rate
Settings 0, 2 and 4 are not
used by IPLB.
0 = V.27ter, 2400bps
1 = V.27ter, 4800bps
2 = V.29, 7200bps
3 = V.29, 9600bps
4 = V.17, 12000bps
5 = V.17, 14400bps
5
55
High Speed Data Packet
Length
Not used by IPLB.
1 = 10ms
2 = 20ms
3 = 30ms
4 = 40ms
4
56
Low Speed Redundancy
Settings 0~2 are valid for
IPLB. If a setting higher than
2 is set, the system setting is
kept at 2.
0~5
0
57
High Speed Data Packet
Redundancy
0~2
0
58
TCF Handling Method
0 = Receive TCF
signal by VoIPDB
1 = Through TCF
signal to external
FAX
1
59
Maximum Low Speed Data
Packetization
Not used by IPLB.
1~65535 bytes
1
60
Transmit Network Timeout
Not used by IPLB.
10~32000sec
150
61
T.38 RTP Format Payload
Number
96~127
100
Input Data (Continued)
Item
No.
Item
Input Data
Default