NEC Univerge SV8100 Programming Manual - 15-27 : Power Saving Setup
Other manuals for Univerge SV8100:
Service Information Bulletin, Description, User Manual, User Manual, Quick Start User Manual, User Manual, Information Sheet, User Manual, System Specifications, Configuration Manual, User Manual, User Manual, Quick Reference Manual, Quick Reference Manual, Programming Manual, General Description Manual, User Manual, System Maintenance Manual, User Manual, Features And Specifications Manual, Quick Manual, Features And Specifications Manual, Features And Specifications Manual, Features And Specifications Manual, Features And Specifications Manual, Features And Specifications Manual, Features And Specifications Manual, User Manual, Installation Manual, Installation Manual, Reference Manual, User Manual, System Hardware Manual, Reference sheet, Reference Sheet, Quick Start & Reference Manual, System Configuration Manual, User Manual, User Manual, Programming Manual, Administrator's Manual, User Manual, Quick Reference Manual, Quick Reference Manual, User Manual, User Manual, System Hardware Manual, Installation Manual, Condensed User's Manual, Installation Manual, Quick Reference Manual, System Hardware Manual, User Manual, Installation Manual, Administration Manual, Quick Reference Manual, System Hardware Manual, Features & Specifications Manual, Adminstrators Manual, System Hardware Manual, Applications, System Hardware Manual, User Manual, Installation Manual, Reference Sheet
of
966
UNIVERGE SV8100
Issue 11.0
SV8100 Programming Manual
2 - 221
Description
Use Program 15-27 : Power Saving Setup to set the power saving mode for
extensions.
Conditions
None
Feature Cross Reference
None
Program 15 : Extension, Basic Setup
15-27 : Power Saving Setup
Level:
IN
Input Data
Extension Number
Up to eight digits
Item
No.
Item
Input Data
Default
01
Power Saving Group
Number
0 = Power Save Off
1 ~16 = Power Save Group
0
02
Power Save during
Power Failure
0 = Disable (Power supply)
1 = Enable (Power cut off)
0