NEC Univerge SV8100 Programming Manual - page 268
Issue 11.0
UNIVERGE SV8100
2 - 226
Program 16 : Department Group Setup
Description
Use Program 16-02 : Department Group Assignment for Extensions to set the
Department Groups. The system uses these groups (64 Department Groups) for
Department Calling. Assign pilot numbers to Department Groups you set up in
Program 11-07. This lets system users place calls to the departments. Use Program
16-01 to set the priority of each extension in each Department Group. When a call
comes to the group, the extensions ring in order of their priority.
Conditions
None
Feature Cross Reference
Department Calling
Program 16 : Department Group Setup
16-02 : Department Group Assignment for Extensions
Level:
IN
Input Data
Extension Number
Maximum 8 digits
Item
No.
Group
Number
Priority
Default
Description
Related
Program
01
1~64
1~999
1 – xxx
(See
Note)
Set up the Department Group called
by the pilot number and the extension
priority when a group is called.
Call Pickup Groups are set up in
23-02.
11-07
16-01
The initial value of a priority becomes the ports numerical order assigned in Program 11-02 and 11-04.
(Extension ports are 1~ 256. Virtual extension ports are 1~256.)