NEC Univerge SV8100 Programming Manual - page 351
UNIVERGE SV8100
Issue 11.0
SV8100 Programming Manual
2 - 309
12
Dial E911 Routing Without Trunk
Access
If enabled (1), an extension user can
dial 911 (USA only) without first
dialing a trunk access code or
pressing a line key. If disabled (0), an
extension user must dial a trunk
access code (e.g., 9) or press a line
key before dialing 911 (USA only).
0 = Trunk Access
Code
Required
1 = Trunk Access
Code Not
Required
1
13
Alarm Ring Timer (E911)
Set the duration of the E911 Alarm
Ring Time. If set for 0, the E911 Alarm
does not ring.
0, 1~64800 (sec)
(0 = Off)
0
11-12-56
20-08-16
14
Forced Account Code Inter-digit
Timer
The system waits this time for a user
to enter a Forced Account code.
0~64800
(sec)
3
15
Outgoing Disable on Incoming Line
(Toll Restriction)
Enable/Disable the Outgoing Disable
on Incoming Line feature.
0 = Disable (Off)
1 = Enable (On)
0
15-01-05
21-01-16
21-01-17
16
Supervise Dial Detection Timer
With the Outgoing Disable on
Incoming Line feature, if dial tone is
not detected after the extension
answers an incoming line, the system
determines the call is unable to
complete and releases the DTMF
receiver.
0~64800 (sec)
20
15-01-05
21-01-16
21-01-17
17
Restriction Digit in Outgoing
Disable on Incoming Line
With the Outgoing Disable on
Incoming Line feature, determine the
number of digits to be dialed before
the call should be disconnected.
Digits 0~9
4
15-01-05
21-01-15
21-01-16
18
Reset Dial After Failure of Trunk
Access
Enable/Disable the ability to continue
to dial codes or extensions after
receiving Trunk Busy. This must be
set to 1 for the Forced Trunk
Disconnect feature to work.
0 = Disable (Off)
1 = Enable (On)
1
19
--- Not Used ---
Input Data (Continued)
Item
No.
Item
Input Data
Default
Related