NEC Univerge SV8100 Programming Manual - page 52
Issue 11.0
UNIVERGE SV8100
2 - 10
Program 10 : System Configuration Setup
10
Master/Slave System
If set to 0, system is synchronized to the
network clock. If set to 1, system is not
synchronized to the network clock. (For
NW Mode)
0 = Slave System
1 = Master System
0
11
Networking System No. (for NW
Mode)
0~50
0
14
--- Not Used ---
15
--- Not Used ---
17
ISDN Line Ringback Tone
If Telco does not provide ringback tone,
SV8100 can if set to 1 (Enable).
0 = Disable
1 = Enable
0
18
Type of Number
ISDN Protocol definition
0 = Unknown
1 = International number
2 = National number
3 = Network specific number
4 = Subscriber number
5 = Abbreviated number
2
19
Numbering Plan Identification
ISDN Protocol definition
0 = Unknown
1 = ISDN numbering plan
2 = Data numbering plan
3 = Telex numbering plan
4 = National standard numbering plan
5 = Private numbering plan
1
23
Straight/Cross Wiring
0 = Auto
1 = Manual (Cross)
2 = Manual (Straight)
0
24
--- Not Used ---
25
Layer 1 Supervision
When set to 0, Layer 1 deactivation is
not considered to be a fault, so the
channel can be usable and alarm #10
not issued. When set to 1, Layer 1
deactivation is considered to be a fault,
so the channel will be skipped and
alarm #10 issued.
0 = Disable
1 = Enable
0
Item
No
Item
Input Data
Default