NEC Univerge SV8100 Programming Manual - 84-06 : Pva Data Setting
UNIVERGE SV8100
Issue 11.0
SV8100 Programming Manual
2 - 751
Description
Use Program 84-06 : PVA Data Setting
to set up threshold levels of every CD-PVAA
slot.
(This program is not available with Version 1000)
Program 84 : Hardware Setup for VoIP
84-06 : PVA Data Setting
Level:
IN
Input Data
Slot Number
01~24
Item
No.
Item
Input Data
Default
Description
01
RTP Port Number
0~65534
10020
02
RTCP Port Number
RTP Port Number + 1
10021
It has to be RTP Port Number
+ 1.
04
Fract Lost Threshold
0~100%
0
The data is sent to the
CD-CP00-US if the value
exceeds the defined value.
05
Packets Lost
Threshold
0~16777215
0
The data is sent to the
CD-CP00-US if the value
exceeds the defined value.
07
Jitter Threshold
0~4294967295 (sec)
0
The data is sent to the
CD-CP00-US if the value
exceeds the defined value.
09
Delay LSR Threshold
0~4294967295 (sec)
0
The data is sent to the
CD-CP00-US if the value
exceeds the defined value.
16
IMCP Redirect
0=No
1=Yes
0
The VOIP blade supports
sending the Internet Message
Control Protocol (IMCP)
redirect message.