NEC Univerge SV8100 Programming Manual - page 197
UNIVERGE SV8100
Issue 11.0
SV8100 Programming Manual
2 - 155
Conditions
None
Feature Cross Reference
None
14
Loop Start/Ground Start
0 = Loop Start (Loop)
1 = Ground Start
(Ground)
0
16
--- Not Used ---
17
Sync. Ringing
Specify whether or not CO/PBX calls
follow Synchronous Ringing.
Synchronous Ringing does not
apply to incoming DID calls,
off-hook ringing calls, or CO/
PBX ring transfer calls.
0 = Disable
1 = Enable
1
18
Busy Tone Detection on Talking
0 = Disable
1 = Enable
0
19
Busy Tone Detection Frequency
1~255
1
14-02-18
20
Busy Tone Detection Interval
0 = No
1 = Yes
0
14-10
21
Fax Branch Connection
0 = No
1 = Yes
0
23
Caller ID Receiving Method
Rings extension before receiving
Caller ID (1) or after receiving Caller ID
(0).
0 = Wait Caller ID
1 = Immediate Ring
1
Item
No.
Item
Input Data
Default
Related
Program