NEC Univerge SV8100 Programming Manual - page 719
UNIVERGE SV8100
Issue 11.0
SV8100 Programming Manual
2 - 677
Conditions
None
Feature Cross Reference
None
04
Max. detect level
0~15
MF Tone 1 : -5dBm(0) to -20dBm(15)
MF Tone 2 : -10dBm(0) to -25dBm(15)
MF Tone 3 : -15dBm(0) to -30dBm(15)
MF Tone 4 : -20dBm(0) to -35dBm(15)
MF Tone 5 : -25dBm(0) to -40dBm(15)
MF Tone 6 : -30dBm(0) to -45dBm(15)
05
Twist level
0~9 (1dB~10dB)
06
S/N ratio
0~4 (-5step, 0dB~ -20dB)
07
ON detect time
1~255 (15step, 30ms~3840ms)
08
OFF detect time
1~255 (15step, 30ms~3840ms)
Input Data
Item
No.
Item
Input Data
Table 2-19 Default Table
Item
Name
Type 1
Type 2
Type 3
Type 4
Type 5
01
Detect Level
0
0
0
0
0
02
Start delay time
0
0
0
0
0
03
Min. detect level
10 (-20dBm)
10 (-20dBm)
10 (-20dBm)
10 (-20dBm)
10 (-20dBm)
04
Max. detect level
2 (-2dBm)
2 (-2dBm)
2 (-2dBm)
2 (-2dBm)
2 (-2dBm)
05
twist level
5 (6dBm)
5 (6dBm)
5 (6dBm)
5 (6dBm)
5 (6dBm)
06
S/N ratio
2 (-10dBm)
2 (-10dBm)
2 (-10dBm)
2 (-10dBm)
2 (-10dBm)
07
ON detect time
1 (30ms)
1 (30ms)
1 (30ms)
1 (30ms)
1 (30ms)
08
OFF detect time
1 (30ms)
1 (30ms)
1 (30ms)
1 (30ms)
1 (30ms)