NEC Univerge SV8100 Programming Manual - page 771
UNIVERGE SV8100
Issue 11.0
SV8100 Programming Manual
2 - 729
Description
Use Program 82-11 : LCA Initial Data Setup to define the various timers for LCA
Packages.
Conditions
None
Feature Cross Reference
None
Program 82 : Basic Hardware Setup for Extension
82-11 : LCA Initial Data Setup
Level:
IN
Input Data
Item
No.
Item
Description
Input
Default
01
Bounce Protect Time
Specify a time for detection of a
valid off-Hook indication that is long
enough to prevent an unintentional
bounce of the receiver from being
detected as a new Off-Hook
indication from a Single Line
Telephone.
0 = No Setting
1~15 = 100ms~1.5sec
3
(300ms)
02
HookFlash Start Time
Specify the minimum hookflash
time from a Single Line Telephone
or analog Voice Mail system before
it is detected as the beginning of a
valid hookflash.
0 = 40ms
1~15 = 90ms~790ms
5
(450ms)
03
HookFlash End Time
Specify the maximum hookflash
duration from a Single Line
Telephone to receive a second dial
tone.
0 = HST+0ms
1~15 = HST+100ms~HST+1500ms
(HST=Hookflash Start Time)
7