NEC Univerge SV8100 Programming Manual - page 737
UNIVERGE SV8100
Issue 11.0
SV8100 Programming Manual
2 - 695
52
Receive HookFlash Duration
Min. Time (E&M)
1~255
(100ms ~ 25500ms)
3
300ms
53
Receive HookFlash Duration
Max. Time (E&M)
1~255
(100ms ~ 25500ms)
6
600ms
54
Receive HookFlash Duration
Min. Time (OPX)
1~255
(100ms ~ 25500ms)
3
300ms
55
Receive HookFlash Duration
Max. Time (OPX)
1~255
(100ms ~ 25500ms)
6
600ms
56
Loop Off Guard Time (Loop)
1~255
(100ms ~ 25500ms)
20
2000ms
57
Loop Off Guard Time (Ground)
1~255
(100ms ~ 25500ms)
20
2000ms
58
Loop Off Guard Time (DID)
1~255
(100ms ~ 25500ms)
20
2000ms
59
Loop Off Guard Time (E&M)
1~255
(100ms ~ 25500ms)
20
2000ms
60
Loop Off Guard Time (OPX)
1~255
(100ms ~ 25500ms)
20
2000ms
61
Double Ringing Send Time 1
(OPX)
1~255
(100ms ~ 25500ms)
5
500ms
62
Double Between Ringing Send
Time 1 (OPX)
1~255
(100ms ~ 25500ms)
5
500ms
63
Double Ringing Send Time 2
(OPX)
1~255
(100ms ~ 25500ms)
25
2500ms
64
Double Between Ringing Send
Time 2 (OPX)
1~255
(100ms ~ 25500ms)
30
3000ms
65
Single Ringing Send Time (OPX)
1~255
(100ms ~ 25500ms)
10
1000ms
66
Receive DP Make Max. Time
(ALL)
1~255
(100ms ~ 25500ms)
9
900ms
67
Receive DP Break Min. Time
(ALL)
1~255
(100ms ~ 25500ms)
9
900ms
68
Receive DP Break Max. Time
ALL)
1~255
(100ms ~ 25500ms)
9
900ms
69
Single Between Ringing Send
Time (OPX)
1~255
(100ms ~ 25500ms)
9
900ms
70
Guard Time 1 (Loop)
1~255
(100ms ~ 25500ms)
9
900ms
Item
Name
Input Data