NEC Univerge SV8100 Programming Manual - page 884
Issue 11.0
UNIVERGE SV8100
2 - 842
Program 90 : Maintenance Program
13
0
0
Charge
Management
Link Error
The link with the charge
management device came
off.
1. Wiring problem
in connecting
main device with
charge
management
device.
2. PC Problem.
1. Confirm that there is
no problem in wiring
to connect a main
device with the
charge management
device. (Whether
ping passes for LAN
connection is
confirmed.)
2. Restart the charge
management
software.
3. Reboot PC, and start
charge management
software.
When the
connection
returns
normally, the
error is
recovered.
ERR
REC
14
0
0
LAN Link
Error
The link with LAN on
CD-CP00-US came off.
1. LAN cable
defective.
2. Connected HUB
broken.
3. Defective
CD-CP00-US.
Confirm the operation
of LAN connector, LAN
cable, and HUB again.
When the
connection
returns
normally, the
error is
recovered.
ERR
REC
15
0
0
Network Keep
Alive
1. The network connection
has been cut.
2. Network Keep Alive
restoration.
3. Response notification on
network Keep Alive.
1. LAN cable is
defective.
2. Net side trouble.
3. Packet blocked
by firewall.
4. Repetition of IP
address.
1. Confirm that the
defect is on the
Network side.
2. Confirm the settings
of HUB and the
router, etc.
When the
connection
returns
normally, the
error is
recovered.
ERR
REC
WAR
16
0
0
SMDR Link
17
1
0
Denial of
service
The system received an
illegal packet.
Service outage
(DOS
Confirm that the defect
is on the Network side.
WAR
18~28
--- Reserved ---
29
0
0
Charge
Management
Buffer full
The temporary buffer for
the charge management in
main device overflowed,
and a part of unoutput
charge data disappeared
because it could not output
the charge management
data.
1. The charge data
is printed and
not deleted at
the simple
charge
management.
2. The charge data
is not output to
PC for the
charge
management
software.
1. Print and delete the
charge data at the
simple charge
management.
2. Connect the charge
management
software for the
charge management
software and output
the charge data.
When the
output is
restarted, the
error is
recovered.
However, the
charge
management
data after the
error occurs is
not recorded.
ERR
REC
30
2
0
SMDR Buffer
full
The temporary buffer for
SMDR in main device
overflowed, and a part of
unoutput SMDR data
disappeared because it
could not output SMDR
data.
1. Problem of
wiring to
connect main
device with PC.
2. PC Problem.
1. Confirm whether
there is problem in
wiring to connect a
main device with
PC.
2. Execute the
reactivation of PC.
When the
output is
restarted, the
error is
recovered.
However, the
SMDR data
after the error
occurs is not
recorded.
ERR
REC
31
1
0
Auto Dial after
Sensor
Detection
Auto dialing occurs after
sensor detection.
Sensor detect an
abnormality and
makes an
emergency call.
No action needed.
Table 2-20 Description of Alarm (Continued)
Alarm
No.
Type
Report
Name
Content of Alarm
Cause
Action
Recovery
Alarm
Status