NEC Univerge SV8100 Programming Manual - page 760
Issue 11.0
UNIVERGE SV8100
2 - 718
Program 82 : Basic Hardware Setup for Extension
Item
No.
Item
Input Data
01
Frequency 1
1 = 520Hz
2 = 540Hz
3 = 660Hz
4 = 760Hz
5 = 1100Hz
6 = 1400Hz
7 = 2000Hz
02
Frequency 2
03
Modulation
0 = No Modulation
1 = 8Hz Modulation
2 = 16Hz Modulation
3 = Envelope
Default
Incoming Ringing Tone
Number
Tone
Type
Frequency 1
(Hz)
Frequency 2
(Hz)
Modulation
Pattern 1
(Trunk Incoming)
High
Mid
Low
1100
660
520
1400
760
660
16Hz Modulation
16Hz Modulation
16Hz Modulation
Pattern 2
(Trunk Incoming)
High
Mid
Low
1100
660
520
1400
760
660
8Hz Modulation
8Hz Modulation
8Hz Modulation
Pattern 3
(Trunk Incoming)
High
Mid
Low
2000
1400
1100
760
660
540
16Hz Modulation
16Hz Modulation
16Hz Modulation
Pattern 4
(Trunk Incoming)
High
Mid
Low
2000
1400
1100
760
660
540
8Hz Modulation
8Hz Modulation
8Hz Modulation
Pattern 5
Intercom Incoming Pattern
High
Mid
Low
1100
660
520
1400
760
660
8Hz Modulation
8Hz Modulation
8Hz Modulation
Pattern 6
Alarm Sensor Pattern
High
Mid
Low
760
760
760
760
760
760
No Modulation
No Modulation
No Modulation
Pattern 7
(Trunk Incoming)
High
Mid
Low
1400
760
660
540
540
540
16Hz Modulation
16Hz Modulation
16Hz Modulation
Pattern 8
(Trunk Incoming)
High
Mid
Low
1400
760
660
540
540
540
8Hz Modulation
8Hz Modulation
8Hz Modulation
Pattern 9
(Trunk Incoming)
High
Mid
Low
2000
2000
1100
1100
540
760
16Hz Modulation
16Hz Modulation
16Hz Modulation