Description
Use Program 84-23 : DT700 Multiline Basic Information Setup
to set the basic
information for the DT700 Multiline Terminal.
Program 84 : Hardware Setup for VoIP
84-23 : DT700 Multiline Basic Information Setup
Level:
IN
Input Data
Item
No.
Item
Input Data
Default
01
Registration Expire Timer
The Expires value of the REGISTER
message which received from DT700
terminal is out of range or when the Expire
value is not set up, in case it assigns the
effective time to the DT700 terminal. The
timer for supervising whether DT700 terminal
is connected or not.
60~65535 (sec)
180
02
Subscribe Expire Timer
The subscribe Expire timer to transmit and
receive the terminal operation instructions
between the Main Device and DT700
terminal.
60~65535 (sec)
3600
03
Session Expire Timer
Set effective time for supervising the Voice
Path.
60~65535 (sec)
180
04
Minimum Session Expire Timer
Set minimum value of effective time for
supervising the Voice Path.
60~65535 (sec)
180
05
Invite Expire Timer
Set effective time for Incoming/Outgoing call
when the Expire value is not set in the
INVITE message received from DT700
terminal.
0~65535 (sec)
180
06
Signal Type of Service
Set Type of Service value which applied to
send SIP Message Packet from DT700
terminal to Main Device.
0x00~0xFF
(0~9, A~F)
00
07
Error Display Timer
0~65535 (sec)
0