13
TDM TX HLC Threshold
Select HLC threshold level.
Effective when 84-31-10 = 3
0~42 (-42 ~ 0)
0 = -42dBm
1 = -41dBm
:
41 = -1dBm
42 = 0dBm
41
14
TDM TX Gain Compression
Mode
Transmit Gain Compression on or
off. Effective when 84-31-10 = 3
0 = Disable
1 = Enable
1
15
TDM TX Gain Compression
Threshold
Transmit Gain Compression
threshold. Effective when 84-31-14
= 1
0~42 (-42 ~ 0)
0 = -42dBm
1 = -41dBm
:
41 = -1dBm
42 = 0dBm
41
16
TDM RX Level Control
Normally not used. Select receive
level control mode.
0 = Disable
1 = RX Level Control Mode
2 = RX Automatic Level Control
Flag
0
17
TDM RX Level Control Level
Normally not used. Select receive
voice level. Effective when
84-31-16 = 1
0~16 (-24 ~ +24)
0 = -24dB
1 = -21dB
:
8 = 0dB
:
15 = 21dB
16 = 24dB
8
18
TDM RX Automatic Level
Control Level
Normally not used. Select target
gain. Effective when 84-31-16 = 2
0~12 (-42 ~ -6)
0 = -42dBm
1 = -39dBm
:
7 = -21dBm
:
11 = -9dBm
12 = -6dBm
7
19
RTP Echo Canceller Mode
Select echo canceller on/off at
sending (RTP) side.
0 = Disable
1 = Enable
0
20
RTP Echo Canceller NLP Mode
Select echo compression mode on
or off for remaining echo. Effective
when 84-31-19 = 1
0 = Disable
1 = Enable
0
Input Data (Continued)
Item
No.
Item
Input Data
Default