Program 81 : Basic Hardware Setup for Trunk
Description
Use Program 81-03 : ODT Initial Data Setup
to define the various basic timers for
the E&M Tie Line Unit.
Program 81 : Basic Hardware Setup for Trunk
81-03 : ODT Initial Data Setup
Level:
IN
Input Data
Item
Name
Input Data
Default
01
PCM Method Type
0 =
-law
1= A-law
0
02
Answer Signal Time
1~255
(10~2550ms)
6
(60ms)
03
Clear Signal (Open Loop) Detection Time
1~255
(100~25500ms)
7
(700ms)
04
Ringing Signal Detection Minimum Time
1~255
(10~2550ms)
10
(100ms)
05
Ringing Signal Stop Detection Time
1~255
(100~25500ms)
7
(700ms)
06
Hook Flash Time
1~255
(10~2040ms)
20
(200ms)
07
Pause Time
1~255
(60~15300ms)
50
(3000ms)
08
WINK/DELAY Duration Time
1~255
(10~2550ms)
20
(200ms)
09
Incoming-WINK/DELAY Send Time
1~255
(100~25500ms)
3
(300ms)
10
Seizure-WINK/DELAY Receive Max. Time
1~255
(100~25500ms)
48
(4800ms)
11
Receive WINK/DELAY Duration Min. Time
1~255
(10~2550ms)
13
(130ms)
12
Receive WINK/DELAY Duration Max. Time
1~255
(10~2550ms)
31
(310ms)
13
Receive DP Make Minimum Time
1~255
(2~510ms)
5
(10ms)