NEC Univerge SV8100 Programming Manual - 90-10 : System Alarm Setup
UNIVERGE SV8100
Issue 11.0
SV8100 Programming Manual
2 - 839
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You
can designate an alarm as Major or Minor. This program also assigns whether or not
the alarm information is reported to the predefined destination.
Program 90 : Maintenance Program
90-10 : System Alarm Setup
Level:
IN
Input Data
Alarm Number
001~100
Item
No.
Item
Input Data
01
Alarm Type
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
02
Report
0 = Not Report (No autodial)
1 = Report (autodial)
Table 2-20 Description of Alarm
Alarm
No.
Type
Report
Name
Content of Alarm
Cause
Action
Recovery
Alarm
Status
1
2
0
PKG Initialize
Error.
1. The PKG failed to
initialize.
2. The PKG did not start
normally.
1. PKG not inserted
firmly.
2. PKG was
removed, but not
reinserted firmly.
3. Old PKG data
still reported due
to no
initialization.
1. Insert PKG firmly.
2. Insert PKG firmly.
3. Delete slot
information in
PRG 90-05 and
insert the PKG
again.
During
initialization,
the PKG is
recognized.
ERR
REC
2
2
0
PKG
Mounting
Error
The unit did not step on a
regular procedure and it
was pulled out. Or, it is not
normally inserted.
1. The package is
not completely
inserted.
2. The package is
out of order.
1. Insert the package
firmly.
2. Try again after
initializing the
system data once
when LED doesn't
blink normally.
3. Exchange packages.
When unit is
reconfirmed,
the error is
recovered.
ERR
REC