NEC Univerge SV8100 Programming Manual - page 742
Issue 11.0
UNIVERGE SV8100
2 - 700
Program 81 : Basic Hardware Setup for Trunk
Description
Use Program 81-10 : COT Initial Data Setup to define the various basic timers for
each COT trunk port. These timers are only used with a Migration system and only
apply to the Circuit cards installed in the IPKII/IPK chassis. These timers do not apply
to SV8100 blades.
Program 81 : Basic Hardware Setup for Trunk
81-10 : COT Initial Data Setup
Level:
IN
Input Data
Trunk No.
1~ 200
Item
No.
Item
Input Data
Default
01
DP Interdigit Time Selection
The DP Interdigit Time is the minimum
pause time between dial pulses. Select
either Pattern A or pattern B.
0 = Pattern A
(Pattern A: 10pps – 650ms,
20pps – 50ms)
1 = Pattern B
(Pattern B: 10pps – 800ms,
20pps – 80ms)
1
(Pattern B)
02
Prepause Time Selection
Specify the loop open time for a hookflash
signal sent to the CO or PBX when the
Recall key on a multiline terminal is
pressed. A single line telephone (SLT)
generates a hookflash to the CO or PBX
line when a SLT hookflash is assigned.
1~13
(1~13 seconds)
(0 = No Setting)
1
(1sec)
03
Incoming Signal Detect Time Selection
Specify the time after the incoming signal
from another system is detected before the
acknowledge signal is sent out.
0~15
(50~800ms)
3
(200ms)
04
Disconnect Recognition Time Selection
Specify the minimum time before a
disconnected circuit can be accessed
again.
1~15
(100ms~1.5 seconds)
(0 = No Setting)
3
(300ms)
05
Auto Release Signal Detection Time
Specify the signal detection time for release
of a CO/PBX line after a disconnect signal is
received from the distant CO or PBX.
1~14
(50~700ms)
15 = (No limit)
(0 = No Setting)
7
(350ms)