NEC Univerge SV8100 Programming Manual - page 222
Issue 11.0
UNIVERGE SV8100
2 - 180
Program 15 : Extension, Basic Setup
Conditions
None
Feature Cross Reference
Refer to the Input Data chart.
Table 2-4 Lamp Cycle On/Off Timing Pattern
Programs 15-02-35, 36, and 38
Input
Cycle
1
Cycle 1
500ms – ON / 500ms – OFF
2
Cycle 2
250ms – ON / 250ms – OFF
3
Cycle 3
125ms – ON / 125ms – OFF
4
Cycle 4
125ms – ON / 125ms – OFF / 125ms – ON / 625ms – OFF
5
Cycle 5
875ms – ON / 125ms – OFF
6
Cycle 6
625ms – ON / 125ms – OFF / 125ms – ON / 125ms – OFF
7
Cycle 7
1000ms – ON
Table 2-5 Program 15-02 – Incoming Signal Frequency Patterns
Incoming Signal
Frequency Pattern
Type
Frequency 1
Frequency 2
Modulation
External Incoming Signal
Frequency (Pattern 1)
High
Middle
Low
1100
660
520
1400
760
660
16Hz
16Hz
16Hz
External Incoming Signal
Frequency (Pattern 2)
High
Middle
Low
1100Hz
660Hz
520Hz
1400Hz
760Hz
660Hz
8Hz
8Hz
8Hz
External Incoming Signal
Frequency (Pattern 3)
High
Middle
Low
2000Hz
1400Hz
1100Hz
760Hz
660Hz
540Hz
16Hz
16Hz
16Hz
External Incoming Signal
Frequency (Pattern 4)
High
Middle
Low
2000Hz
1400Hz
1100Hz
760Hz
660Hz
540Hz
8Hz
8Hz
8Hz
Internal Incoming Signal
Frequency
High
Middle
Low
1100Hz
660Hz
520Hz
1400Hz
760Hz
660Hz
8Hz
8Hz
8Hz