NEC Univerge SV8100 Programming Manual - page 744
Issue 11.0
UNIVERGE SV8100
2 - 702
Program 81 : Basic Hardware Setup for Trunk
Description
Use Program 81-11 : Tie Line Initial Setup to define the various initial data for DID/
TLI/DTI packages.
Program 81 : Basic Hardware Setup for Trunk
81-11 : Tie Line Initial Setup
Level:
IN
Input Data
Trunk No.
1~ 200
Item
No.
Item
Input Data
Default
01
DP Interdigit Time Selection
The DP Interdigit Time is the minimum
pause time between dial pulses. Select
either Pattern A or pattern B.
0 = Pattern A
(Pattern A: 10pps – 650ms,
20pps – 500ms)
1 = Pattern B
(Pattern B: 10pps – 800ms,
20pps – 800ms)
1
02
Prepause Time Selection
Specify the loop open time for a hookflash
signal sent to the Tie Line when the Recall
key on a multiline terminal is pressed. A
Single Line Telephone (SLT) generates a
hookflash to the Tie Line when a SLT
hookflash is assigned.
1~4
(1~4 = 0.5~2.0 seconds)
(5~15 = 3.0~13 seconds)
(0 = No Setting)
0
(No Setting)
03
Tie Line Answer Detect Time Selection
Specify the time before a UNIVERGE
SV8100 system answer (Off-Hook) is
recognized as an answer.
0~15
(130ms~1950ms)
(0 = No Setting)
4
(520ms)
04
Tie Line Release Detect Time Selection
Specify the circuit disconnect detected on
the Tie Line on the distant system side is
recognized as Tie Line.
0~15
(130ms~1950ms)
(0 = No Setting)
4
(520ms)