NEC Univerge SV8100 Programming Manual - page 711
UNIVERGE SV8100
Issue 11.0
SV8100 Programming Manual
2 - 669
Default
03
S/N Ratio
0~4 (0dB ~ -20dB)
04
No Tone Time
0~255 (30+30~7680ms)
(0 = not detect)
1~255 = 60~7680ms.
The formula is 30+30N.
When set to N=1, it means 30+30*1=60
When set to N=255, it means
30+30*255=7680
05
Pulse Count
1~255
06
ON Minimum Time
1~255 (30+30~7680ms)
07
ON Maximum Time
0~255 (30+30~7680ms)
08
OFF Minimum Time
1~255 (30+30~7680ms)
09
OFF Maximum Time
0~255 (30+30~7680ms)
12
Frequency No. 1
1~8 (Frequency Table No. set by 80-07)
13
Frequency No. 2
0~8 (Frequency Table No. set by 80-07)
Item No
Item
Input Data
Item
Name
Type 1 (DT)
Type 2 (BT)
Type 3 (RBT)
Type 4
Type 5
1
Detect Level
0 (-25dBm)
0 (-25dBm)
0 (-25dBm)
0 (-25dBm)
0
2
Min. detect level
15 (-25dBm)
15 (-25dBm)
15 (-25dBm)
15 (-25dBm)
0
3
S/N ratio
4 (-20dB)
4 (-20dB)
4 (-20dB)
1
0
4
No tone time
132 (3990ms)
132 (3990ms)
132 (3990ms)
132 (3990ms)
0
5
Pulse Count
1
1
1
2
2
6
ON min. time
9 (300ms)
12 (390ms)
23 (720ms)
3 (120ms)
2
7
ON max. time
0 20
(630ms)
74
(2256ms)
13 (420ms)
5
8
OFF min. time
1 (60ms)
12 (390ms)
59 (1800ms)
3 (120ms)
2
9
OFF max. time
1 (60ms)
20 (630ms)
232 (6990ms)
13 (420ms)
5
12
Frequency No. 1
1
3
2
3
1
13
Frequency No. 2
2
4
3
4
2