Use Program 81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup
to define the
various basic timers for layer 3 of ISDN BRI/PRI (defined in Program 10-03-04).
Program 81 : Basic Hardware Setup for Trunk
81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup
Level:
IN
Input Data
Layer 3 Timer Type Number
1~5
Item
No.
Item
Description
Input Data
Default
01
T301
Specify the timer value started when
the ALERT message is received.
0,180~254 (sec)
180
02
T302
Specify the timer value started when
the SETUP ACK is sent. Timer is also
restarted when INFO is received.
1~254 (sec)
15
03
T303
Specify the timer value started when
SETUP is sent.
1~254 (sec)
4
04
T304
Specify the timer value started when
the SETUP ACK is received. Timer is
also restarted when INFO is received.
0~254 (sec).
30
05
T305
Specify the timer value started when
DISC without progress No. 8 is sent.
1~254 (sec)
30
06
T306
Specify the timer value started when
DISC with progress indicator No. 8 is
sent. This timer is valid for Network
side use only.
0~254 (sec)
30
07
T307
Specify the timer value started when
SUSPEND ACK is sent. This timer is
valid for Network side use only.
1~254 (sec)
180
08
T308
Specifies the timer value started when
REL is sent.
1~254 (sec)
4
09
T309
Specify the timer value started at data
link disconnection.
1-254 (sec)
90
10
T310
Specify the timer value started when
CALL PROC is sent.
0~180 (sec)
180
11
T312
Specify the timer value started when
SETUP is sent or re-sent on
broadcast data link. This timer is valid
only for Network side use only.
1~254 (sec)
6