Program 24 : Hold/Transfer Setup
Conditions
None
Feature Cross Reference
Transfer
07
Trunk-to-Trunk Transfer Release Warning
Tone
Time starts when a trunk begins talking with
another trunk (for example: trunk-to-trunk
transfer, outgoing from trunk, Tandem Trunking).
When this time expires, a warning tone is heard.
If Program 24-02-10 is set, the conversation
disconnects after time expires. This time is set
again when the external digit timer expires. One
of the trunks used must be an analog trunk (or
leased line).
0~64800 (sec)
1800
14-01-25
20-28-01
20-28-02
20-28-03
24-02-10
08
Delayed Transfer Time for all Department
Groups
0~64800 (sec)
10
11-11-28
11-11-29
15-07-59
09
Two B-Channel Transfer Retry Timer
0~64800 (sec)
10
10-03-16
(PRI)
10
Disconnect Trunk-to-Trunk
0~64800 (sec)
0
14-01-25
20-28-01
20-28-02
20-28-03
24-02-07
11
No Answer Step Transfer
0~64800 (sec)
10
14-01-26
12
No Answer Trunk-to-Trunk Transfer
0~64800 (sec)
0
14-01-26
13
Hook Flash Sending Timer When the System
Answers Automatically
Time before sending the hook flash for Call
Forward Centrex.
0~64800 (sec)
2
15
SIP Out of Range Timer
When not receiving any response within this
timer setting, system determines SIP terminal is
out of range. When set to 0, timer is invalid.
0~30 (sec)
4
Input Data (Continued)
Item
No.
Item
Input Data
Default
Related
Program