Canon imagePRESS C1 Service Manual - page 1011
Chapter 16
16-114
15. EXP-LED
T-16-117
16.P-PASCAL
Use it if the gradation fault is occurred after executing the printer PASCAL.
T-16-118
ACS-CNT2
Adjust the count area of the chromatic color judgment pixels for ACS.
Adjustment method
When you increase the setting value, the judgment area becomes wider.
2
Adjustment range: -2 to +2
[Factory setting value / Value after RAM clear: 0]
REOS-PG
Select a coefficient of Reos processing at 1200 dpi.
Print a PG of which PG type is set at 55 (55 is set for COPIER>TEST>PG>TYPE). Set an area
number which is likely to realize an optimum character proportion or line width at PDL 1200dpi
setting in the Reos processing module based on this PG. (A PG of which PG type is set at 55 has
four areas, where each image is printed.)
2
Adjustment range: 0 to 4
[Factory setting value / Value after RAM clear: 0]
COPIER > ADJUST > EXP-LED
Subheading Contents
Level
CLN-EXP
Set a cleaner pre-exposure current. (image area)
Set the light volume of cleaner pre-exposure for an image area at printing.
1
Setting range: 5 to 10 (Unit: 10mA)
Standard value: 8
CLN-EXP2
Set the cleaner pre-exposure current. (color/paper internal)
Set the light volume of cleaner pre-exposure for color/paper interval.
1
Setting range: 5 to 10 (Unit: 10mA)
Standard value: 8
PR-EXP
Set a current of the pre-exposure LED when electric potential control is turned off. (Feeding
speed: 1/1 speed)
2
Setting range: 5 to 10 (Unit: 10mA)
Standard value: 8
COPIER > ADJUST > P-PASCAL
Subheading Contents
Level
CS1OFWMY
Adjust the main unit offset of the solid white actual measurement brightness value Y for Color
Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFWIM
Adjust the main unit offset of the solid white ideal brightness value M for Color Sensor
1
Setting range: 0 to 1023
Standard value: 0
CS1OFDMM
Adjust the main unit offset of the solid actual measurement brightness value M for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFDMY
Adjust the main unit offset of the solid actual measurement brightness value Y for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFDIM
Adjust the main unit offset of the solid ideal brightness value M for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFDIY
Adjust the main unit offset of the solid ideal brightness value Y for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFHMM
Adjust the main unit offset of the HT actual measurement brightness value M for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFHMY
Adjust the main unit offset of the HT actual measurement brightness value Y for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFHIM
Adjust the main unit offset of the HT ideal brightness value M for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
COPIER > ADJUST > MISC
Subheading Contents
Level