Canon imagePRESS C1 Service Manual - page 1106
Chapter 16
16-209
F-BLT-RT
Measure at E007 (fixing belt displacement error) occurrence
Specify the host machine operation at E007 occurrence.
1
Setting range: 0 to 1
0: Automatic restore does not take effect at power OFF/ON.
1: Automatic restore takes effect at power OFF/ON.
Standard value 0
This item applies to the upgraded device (DCON Ver11.03 or later and Cont Ver24.04 or later).
W-CLN-P
Set the interval (number of copies) to perform automatic cleaning of the primary charging wire in
the normal environment.
The setting value becomes valid after the main power switch is turned OFF/ON.
2
Setting range
50 to 10000 (copies)
Standard value
2000
W-CLN-T
Set the interval (number of copies) to perform automatic cleaning of the charging wire of the pre-
transfer charging assembly.
2
Setting range
50 to 10000 (copies)
PRI-FAN
Select the primary fan drive mode.
Prevent the half tone unevenness due to the soiled primary charging assembly grid.
2
Setting range
0: Half speed in the high temperature/humidity environment
1: Full speed mainly in the low temperature / low humidity environment.
Standard value
0
The setting value becomes valid after the main power switch is turned OFF/ON.
DH-SW
Perform Dhalf correction.
2
Setting range
0: Do not perform Dhalf control.
1: Perform Dhalf control.
Standard value
1
The setting value becomes valid after the main power switch is turned OFF/ON.
RAW-DATA
Make a setting to print out the received data as it is.
When there is a problem in the received image, this mode is used to determine whether the
problem is caused by the data contents or image processing.
2
Setting range
0: Normal operation
1: Print out the received data as it is.
Standard value
0
COPIER>OPTION>BODY
Subheading Contents
Level