Canon imagePRESS C1 Service Manual - page 1103
Chapter 16
16-206
INTROT-1
Set the image adjustment control implementation interval at last rotation.
1
Setting range: 0 to 500
Standard value: 60
The setting value becomes valid after the main power switch is turned OFF/ON.
INTROT-2
Process auto-adjustment implemented for every specific number of sheet.
Set the interval (sheets) against the process auto-adjustment.
1
Setting range: 50 to 10000 (small image)
Standard value: 2000
The setting value becomes valid after the main power switch is turned OFF/ON.
INTROT-T
Set the interval time of auto-adjustment control (simple control)
1
Setting range
50 to 10000 (small image)
Standard value
400
The setting value becomes valid after the main power switch is turned OFF/ON.
AUTO-DH
Set the permission/prohibition to automatically start the automatic gradation control which is
executed when the machine is left for a specified period time or the environment changes in the
ON/OFF standby condition for automatic gradation correction control.
The setting value becomes valid after the main power switch is turned OFF/ON.
1
Setting range
0: Prohibited
1: Permitted (default)
Standard value
1
ENVP-INT
Set the log acquisition interval for temperature/humidity in the machine and fixing temperature.
Set the log acquisition interval for COPIER>FUNCTION>MISC-P>ENV-PRT and
COPIER>DISPLAY>ENVRNT.
1
Setting range
0 to 480 (minute)
Standard value
60
Reference
Log acquisition not implemented at 0 minute.
T1-TEMP
Switch the down sequence table for thick paper 1.
1
Setting range
0: Default
1: Fixing is prioritized.
2: Productivity is prioritized.
Standard value
0
The setting value becomes valid after the main power switch is turned OFF/ON.
T2-TEMP
Switch the down sequence table for thick paper 2.
1
Setting range
0: Default
1: Fixing is prioritized.
2: Productivity is prioritized.
Standard value
0
The setting value becomes valid after the main power switch is turned OFF/ON.
COPIER>OPTION>BODY
Subheading Contents
Level