Canon imagePRESS C1 Service Manual - page 866
Chapter 15
15-3
15.2 Error Code Details
15.2.1 List of Error Codes
0012-0886
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+
T-15-2
Code
Cause (Detection Description)
Remedy
E000
At power on, the rise in the temperature of the fixing assembly is not high enough.
There is an open circuit or poor contact in the following: main thermistor (THM1, THM3, THM5), sub thermistor (TP1, TP2, TP3), or heater (H1, H2,
H3, H4). The AC driver PCB or DC controller is faulty.
0001 During warm-up, the temperature does not rise after the specified
period of time (300 sec)
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0002 During warm-up, the temperature does not rise after the specified
period of time (after reaching warm-up 1, 360 sec)
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0003 During warm-up, the temperature does not rise after the specified
period of time (after reaching warm-up 2, 300 sec)
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0004 During warm-up, the temperature does not rise after the specified
period of time (after reaching warm-up 3, 360 sec)
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0005 During warm-up after the fixing assembly jam, the temperature
does not rise after the specified period of time (600 sec)
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
E001
The rise in temperature of the fixing assembly is excessive.
There is an open circuit or poor contact in the following: main thermistor (THM1, THM3, THM5), sub thermistor (THM4, THM5, THM6), or heater
(H1, H2, H3, H4). The AC driver PCB or the DC controller PCB is faulty.
0001 The rise in the temperature of the fixing roller is excessive
(hardware detection)
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0002 The rise in the temperature of the external heat roller is excessive
(hardware detection)
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0003 The rise in temperature of the inlet roller is excessive (hardware
detection)
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0004 The rise in temperature of the edge of the external heat roller is
excessive (hardware detection)
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0005 The rise in temperature of the edge of the inlet roller is excessive
(hardware detection)
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0011 The rise in temperature of the fixing roller is excessive .
The fixing main thermistor is 200 deg C or more, and its state
continues for 500 msec.
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
E002
There is an open circuit or poor contact in the following: main thermistor (THM1, THM3, THM5), thermal switch (TP1, TP2, TP3), or heater (H1, H2,
H3, H4). The AC driver PCB or DC controller is faulty.
0010 The temperature of the fixing roller reaches 80 deg C, but drops 50
deg C or less for 1 sec..
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0020 The temperature of the external heat roller reaches 80 deg C, but
drops 50 deg C or less for 1 sec.
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0030 The temperature of the inlet roller reaches 80 deg C, but drops 50
deg C or less for 1 sec.
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
E003
After standby, the drop in temperature of the fixing assembly is excessive.
There is an open circuit or poor contact in the following: main thermistor (THM1, THM3, THM5), thermal switch (TP1, TP2, TP3), or heater (H1, H2,
H3, H4). The AC driver PCB or DC controller is faulty.
0041 During standby, the drop in the temperature of the fixing roller is
excessive: (detecting temperature of the main thermistor or the sub
thermistor)
During standby, the temperature of the fixing roller is 130 deg C
or less for 1 sec
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0042 During standby, the drop in the temperature of the external heat
roller is excessive: (detecting temperature of the main thermistor
or the sub thermistor)
During standby, the temperature of the external heat roller is 160
deg C or less for 1 sec
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0043 During standby, the drop in the temperature of the inlet roller is
excessive: (detecting temperature of the main thermistor or the sub
thermistor)
During standby, the temperature of the inlet roller is 60 deg C or
less for 1 sec
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0051 During black/white printing, the drop in the temperature of the
fixing roller is excessive: (detecting temperature of the main
thermistor or the sub thermistor)
During black/white printing, the temperature of the fixing roller is
100 deg C or less for 1 sec
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0052 During black/white printing, the drop in the temperature of the
external heat roller is excessive: (detecting temperature of the
main thermistor or the sub thermistor)
During black/white printing, the temperature of the external heat
roller is 150 deg C or less for 1 sec
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
0053 During black/white printing, the drop in the temperature of the
inlet roller is excessive: (detecting temperature of the main
thermistor or the sub thermistor)
During black/white printing, the temperature of the inlet roller is
60 deg C or less for 1 sec
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR