Canon imagePRESS C1 Service Manual - page 192
Chapter 2
2-98
F-2-377
4) Fit the key switch unit [1] in the plate [2] in the direction of an arrow.
- 1 screw (binding: M4X6) [3]
F-2-378
5) Put the harness of the key switch unit [1] through the edge saddle [2].
F-2-379
6) Fix the key switch unit [1] in place using two screws [2] removed in step
3).
7) Connect the connector of the Key Switch [3].
F-2-380
8) Attach the upper rear right cover detached in step 1).
9) Connect the host machine's 2 power plugs (back, left) to 2 separate power
supply systems; then, turn on the main power switch.
2.11.4 After Installing the Key Switch Unit
0013-4806
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / image-
PRESS C1+
1) Select a service mode item (COPIER > FUNCTION > INSTALL > KEY)
and enter 1.
2) Following the instructions on the shutdown sequence screen, turn off the
power.
3) Turn the power back to on.
4) Check to see that the message, "Please set the control key" appears on the
control panel.
5) Insert the control key and check to see that copying operation becomes en-
abled.
2.12 Installing the Reader Heater
2.12.1 Checking the Parts
0014-7008
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / image-
PRESS C1+
Prepare the following parts because each part of the heater PCB is assigned
as service part.
F-2-381
T-2-10
2.12.2 Turning Off the Host Machine
0013-3655
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / image-
PRESS C1+
See the host machine installation [Points to note at the main power OFF].
2.12.3 Installation Procedure
0013-3656
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / image-
PRESS C1+
1) Open the DADF or the platen cover.
2) Remove the glass retainer [1].
- 2 screws [2]
3) Remove the copyboard glass [3].
[1]
[2]
[1]
[2]
[3]
[2]
[1]
[3]
[1]
[2]
No.
Name
Part No.
Qty.
[1]
Mirror heater
FK2-0229-000
1 pc.
[2]
Lens heater
FK2-0228-000
1 pc.
[3]*
Relay cable
FM2-5072-000
1 pc.
[4]**
Cable clamp
WT2-0507-000
2 pc.
[5]
Heater harness retainer
FC5-2945-000
1 pc.
[6]
RS tightening screw
(M4X8)
XB3-6400-805
4 pc.
* Not used herein.
** Use one with this machine.
[1]
[4]**
[6]
[2]
[3]*
[5]